Honeywell XNX Universal Transmitter for Toxic and Oxygen Sensors, HART® Output, UL/CSA Approved, Aluminium - XNX-UTAE-NNNNN

The Honeywell XNX Universal Transmitter is a versatile solution for toxic and oxygen gas detection. Compatible with all Honeywell gas sensors, this transmitter offers industry-standard output signals and future-proof flexibility for evolving standards. With user-friendly features such as a multilingual backlit LCD and easy installation, the XNX ensures cost-effective operations and simplified maintenance. Ideal for various applications from offshore platforms to power stations, this transmitter is a reliable choice for effective gas detection.
Source Availablity
Hub Location Quantity Delivery Time
Selected
KSA 1 2 - 3 days
Availability

In stock

SKU XNX-UTAE-NNNNN
Price Unit Each
Price on Request
loader
Loading...

* The ultimate shipping cost will be displayed during the checkout process

Description

Honeywell Analytics XNX Universal Transmitter

The Honeywell Analytics XNX utilizes multiple detection technologies such as point flammable detectors (catalytic and infrared), toxic and oxygen electrochemical cell detectors, and open path infrared detectors. This versatile transmitter interfaces with all these detection methods, providing standard signal outputs tailored to each specific application or site requirements. If the output standards at a site change, the XNX can be reconfigured to meet the new specifications. Additionally, the XNX is designed to be future-proof, accommodating new output modules as industry standards evolve.

A unified transmitter platform for all gas detectors offers significant advantages. Standardized tools and installation procedures reduce installation costs, while a consistent user interface simplifies operation, decreases training time, and minimizes the risk of errors in message interpretation or setting adjustments. Common spare parts further reduce maintenance inventory and costs across all detectors.

The Honeywell XNX allows the application of the most suitable gas detection technologies for each situation, standardizes the interface for these detectors, and provides the flexibility to deliver the necessary signal outputs. With the XNX, the solution is always adaptable.

Key Features

Versatile

  • Compatible with all Honeywell Analytics gas sensors
  • Select the optimal sensor technology for each application
  • Supports all industry-standard output signals
  • Easily adaptable configuration as site needs evolve
  • Future-proof for upcoming output standards

Unified Transmitter Platform

  • Simplified and cost-effective installation
  • Reduced training time and expenses
  • Lower risk of misinterpreting messages
  • Reduced likelihood of incorrect setting adjustments
  • Decreased maintenance and spare parts inventory costs

User-Friendly

  • Easy-to-read multilingual backlit LCD with text, bar graph, digits, and icons
  • Options for local or remote sensor mounting
  • Selectable sink, source, or isolated 4-20mA output to suit wiring preferences
  • Standard HART communications for remote diagnostics and configuration

Cost-Effective Operations

  • Fully configurable via non-intrusive magnetic switches
  • No need for hot work permits
  • Hot-swappable toxic and oxygen sensor cartridges
  • Serviceable catalytic and infrared sensors
  • Auto-inhibit feature during maintenance

Installation-Friendly

  • Integral surface mounting lugs or optional pipe or ceiling mounting brackets
  • Removable "POD" module for terminal access
  • Removable plug/socket type terminal blocks for easier wiring

Typical Applications

  • Offshore oil and production platforms
  • Oil and gas exploration and drilling
  • Refineries
  • Chemical and petrochemical plants
  • Onshore oil and gas terminals
  • Gas transmission
  • Power stations

Specifications

XNX Transmitter High specification universal transmitter for use with a wide range of Honeywell Analytics local or remote gas detectors for the detection of flammable, toxic, and oxygen gas hazards. Suitable for use in Zone 1 and 2 or Zone 21 and 22 hazardous areas, and North American Class I and II Division 1 or 2 areas.
Construction
Material Housing: 5-coat marine finish painted aluminium alloy or 316 stainless steel
Weight (Approx.) Aluminium alloy: 2.8kg (6.2lbs). 316 stainless steel: 5kg (11lbs)
Mounting Surface mount via integral mounting lugs. Optional pipe mounting kit suitable for Ø100mm to 150mm (Ø4” to 6”) pipe. Optional ceiling mounting bracket
Entries 5 conduit/cable entries (2 right, 2 left, 1 bottom). Entry size M25 for ATEX/IECEx versions or ¾"NPT for UL/CSA certified versions
Dimensions 160mm x 197mm x 114mm (6.1" x 7.8" x 4.5")
Environmental
IP Rating IP66 in accordance with EN60529:1992. NEMA 4X
Operating Temperature -40ºC to +65ºC (-40ºF to +149ºF)
Operating Humidity 0-99%RH (non condensing)
Operating Pressure 90-110kPa
Storage Conditions -40ºC to 75ºC (-40ºF to 167ºF), 0-99% non-condensing
Electrical
Input Voltage Range EC and mV versions 16 to 32Vdc, IR version 18 to 32 Vdc (24Vdc nominal)
Max Power Consumption XNX EC (Toxic): 6.2 watts
XNX mV (Catalytic or IR cell): 6.5 watts
XNX IR with Searchpoint Optima Plus: 9.7 watts
XNX IR with Searchline Excel Receiver: 13.2 watts
Current Output Fully configurable isolated 4-20mA & HART® output module providing current sink, current source and isolated modes of operation (supports HART® 6.0 protocol) supplied as standard
Default current output settings:
≥0.0<1.0mA Fault
3mA Fault/Warning
4.0 mA to 20.0mA Normal gas measurement
2.0 mA or 4.0 mA (17.4mA) Inhibit (during configuration/user settings)
22.0mA Maximum over range
The available output range for Inhibit, Warning, Beam Blocked, and Low Signal is from 1 to 4mA. For an over range condition, the range is 20 to 22mA
4-20mA Signal Accuracy +/-1% Full Scale
Functions Supported by HART®
Functions Gas reading
Gas name and units of measurement
4-20mA signal level
General/device information
Installation
Configuration
Forcing of 4-20mA output
Detailed sensor information including:
Optical signal level
Dynamic reserve (Searchline Excel only)
Raw reading
24V supply voltage
Temperature
Calibration and configuration status
Detailed fault and warning information
Fault and alarm history
Zero calibration
Terminals Cage style pluggable with retaining screws for wire diameter 0.5mm2 to 2.5mm2 (approx. 20AWG to 14AWG)
Certification
European ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db
International IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb Ex tb [ia IIIC Da] IIIC T85 Db
North American UL: Class I, Div 1, Groups A, B, C, and D; Class II, Div. 1 Groups F & G / Class 1, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21
FM: AEx D [ia IIC] IIB + H2 T6 -40°C ≤Tamb ≤65°C
Canadian: CSA: Class I, Div 1, Groups B, C, and D; Class II, Div. 1 Groups F & G / Class I, Zone 1 Groups IIB + H2
EMC EN50270:2006 EN61000-6-4:2007
Performance Europe – ATEX, EN45544, EN50104, EN50271:2010, EN13980, EN60079-29-1
North America – UL 913, UL 1203, CSA 22.2 No. 152
IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
Local IS HART® Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable ‘hot’ connection of HC275/375 HART® or equivalent hand-held configurator
Installation Fitted to one of the cable entries on the XNX transmitter. Option can be factory fitted or in the field by a qualified service engineer
Environmental Protection Port protected by cover to IP66/67 when not in use
Relay Module (Optional)
Description Provides three fully user-configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relay. Mutually exclusive with Modbus and/or Foundation Fieldbus™ options
Rating Maximum: 240VAC, 5A (non-inductive load) Minimum: 5V, 10mA (non-inductive load)
Installation Option can be factory installed in display module or in the field by a qualified service engineer
More Information
SKU XNX-UTAE-NNNNN
Usually ships in 2-3 Days
Manufacturer Honeywell
Brand Honeywell
Price Unit Each
Is Featured No
Reviews
Write Your Own Review
You're reviewing: Honeywell XNX Universal Transmitter for Toxic and Oxygen Sensors, HART® Output, UL/CSA Approved, Aluminium - XNX-UTAE-NNNNN
loader
Loading...

check-circle You submitted your review for moderation.

This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.

Product Attachments
loader
Loading...